Outdoor instructions

👋
The Visionary T-mini is IP67 rated, this means you can using indoor or outdoor with specific dust and water conditions.
Image without caption
⚠️
To use the Visionary T-mini in such conditions, you need to use IP67 cable as well.

Operating specification

Characteristic
Value
Rating
IP67
Protection class
III
Vibration resistance
IEC 60068-2-6:2008, IEC 60068-2-64:2008
Shock resistance
IEC 60068-2-27:2008
Electromagnetic compatibility
IEC 61000-6-4:2018 / EN IEC 61000-6-4:2019, IEC 61000-6-2:2005 / EN 61000-6-2:2005 / IEC 61000-6-2:2016 / EN IEC 61000-6-2:2019
Ambient operating temperature
–10 °C … +50 °C
Storage temperature
–20 °C … +80 °C
After a warm-up time of 45 minutes (at ≥ −10 °C) the sensor can also be operated at ambient temperatures from −20 °C.
➡️
Even if the sensor can withstand rain and different outdoor conditions, we recommend to build a “roof protection” above the sensor to prevent : - External shock (risk of moving or damaging the sensor) - Overheating (from sustained sun exposition)

Cables

Use IP67 extender cables for outdoor use :
  • IP67 M12-8p network extender
  • IP67 M12-8p A-coded power extender
Then the indoor accessories can be used in the indoor technical booth
Share