Accessories

👉
We are currently designing accessories better suited for field condition for this sensor, this sections describes the accessories shipped with the device by default

1-to-3 splitter cable

💡
The JT128 comes with a 1-to-3 splitter cable (indoor rating) and a power supply
Image without caption

Power supply

Hesai JT128 power supply
Hesai JT128 power supply
Hesai JT128 power supply
Hesai JT128 power supply
Characteristic
Value
Power port
CNN2 “jack”, (female plug is DC5521)
Specification
12V - 4A / 48W
Polarity
Center pin positive (+), outer barrel negative/ground

Mount

👉
We are currently designing a specific secure mount compatible with standard ceiling and with our Augmenta mini magic armAugmenta mini magic arm Meanwhile here are instructions to build a custom mount
Image without caption
Screw type
SEMS screws (with pre-attached flat washers and lock washers) are recommended. Property class should be at least 4.8.
Screw torque
The base material of the threaded holes is aluminium alloy instead of steel. Refer to the following table for the appropriate screw torque.
Thread size
Recommended screw torque
M2
0.2 to 0.3 Nm
M3
0.5 to 0.6 Nm
M4
1 to 1.5 Nm
M5
2 to 2.5 Nm
M6
3.5 to 4 Nm
Thread service life
  • Ten times. (Each screwing counts as one time, so as each unscrewing.)
  • If threadlocker is used, clean the threaded hole before each retightening. Avoid contact between the cover lens and the cleaner.